DC56E

一.Product Features1Product name DC56E DC pump 2Model No.DC56E3Weight:0.48kg4Life span:≥20000h 5Waterproof Grade:IP686Color:Black7Certification:CE,RoHS8Material of pump shell:PPS+30%GF9N

  • Impeller: Closed Impeller
  • Max head: 14M
  • Weight: 0.48KG
  • Rated voltage: 12Vdc,24Vdc,36Vdc
  • Max flow: 2700L/H
Close
Consulting
Customer service:86-755-27811557

一.Product Features

1

Product name

 DC56E DC pump

2

Model No.

DC56E

3

Weight:

0.48kg

4

Life span:

20000h 

5

Waterproof Grade:

IP68

6

Color:

Black

7

Certification

CE,RoHS

8

Material of pump shell

PPS+30%GF

9

Noise class:

40dB

10

Leakproofness:

1MPa10kg

11

Insulation grade:

H Grade(180°)

12

Working principle:

Centrifugal pump

13

Application

  Cooling circulation pump, booster pump, pumping pump.

二.Range

1

Ambient Temperature

3-phase controller inside for non submersible/controller outside for submersible

2

Liquid Type

Oil, water, and other liquids

3

Liquid Temperature

-30°—100°

3-phase controller inside for non submersible/controller outside for submersible

4

Speed control mode (optional):

PWM Speedamplitude 5V 50-800HZ  Can be customized

0-5V Speed

Potentiometer speed regulationThe resistance range 4.7K~20K

5

Power

DC Power Supply

三.Basic parameters (parameters can be customized)

1

Product model

DC56E-12100PWM

DC56E-12100VR

DC56E-12100S

DC56E-24100PWM

DC56E-24100VR

DC56E-24100S

DC56E-24140PWM

DC56E-24140VR

DC56E-24140S

DC56E-36140PWM

DC56E-36140VR

DC56E-36140S

PWM: PWM(50-800HZ/ 5V)

VR: Potentiometer speed regulation

VS: 0~5V Speed regulation by analog voltage signal

S: Fixed rotational speed

2

Rated Voltage

12V DC

24V DC

24V DC

36V DC


3

Working voltage

5-12V

5-30V

5-26V

5-40V

Within this range, the pump can work normally

4

Rated current

3.5A(4.5A

1.4A(2.2A)

2.7A(3.3A

1.8A(2.2A)

Closed outlet current (open pumping current)

5

power

42W(55W

42W(54W)

65W(80W

65W(80W)

Closed outlet power (open pumping power)

6

Max. Flow rate

2100L/H

2100L/H

2700L/H

2700L/H

Exposure to traffic

7

Max. Head

10M

10M

14M

14M

Static head

8

Min. Input power suply

12V-5A

24V-3A

24V-4A

36V-3A


四.Additional function instructions

1

K-jam protection

When the impurity enters the rotor chamber, the rotor stops running, and the pump stops running as well.

2

Dry run/water shortage protection

When the pump is short of water or idling, the pump will cyclically stop (8 seconds) and run (2 seconds), and the protection strategy can be customized

3

Overloading protection

When the voltage is unstable or exceeds the rated power, the pump will stop working.

4

Power reverse connection

Wrong connection of the power supply(positive and negative), the water pump will stop running, and then re-connected, can work normally.


 

Built-in pump driver

 图片关键词

Suitable for external non-diving occasions


 

Pump driver is external

 图片关键词

Suitable for high temperature, diving installation


Dimensions of pump

图片关键词


Telephone consultation
Products
Online Inquiry