DC56E

一.Product Features1Product name DC56E DC pump 2Model No.DC56E3Weight:0.48kg4Life span:≥20000h 5Waterproof Grade:IP686Color:Black7Certification:CE,RoHS8Material of pump shell:PPS+30%GF9N

  • Impeller: Closed Impeller
  • Max head: 14M
  • Weight: 0.48KG
  • Rated voltage: 12Vdc
  • Max flow: 2700L/H
  • Dimension:
Close
Consulting
Customer service:86-755-27811557

一.Product Features

1

Product name

 DC56E DC pump

2

Model No.

DC56E

3

Weight:

0.48kg

4

Life span:

20000h 

5

Waterproof Grade:

IP68

6

Color:

Black

7

Certification

CE,RoHS

8

Material of pump shell

PPS+30%GF

9

Noise class:

40dB

10

Leakproofness:

1MPa10kg

11

Insulation grade:

H Grade(180°)

12

Working principle:

Centrifugal pump

13

Application

  Cooling circulation pump, booster pump, pumping pump.

二.Range

1

Ambient Temperature

3-phase controller inside for non submersible/controller outside for submersible

2

Liquid Type

Oil, water, and other liquids

3

Liquid Temperature

-30°—100°

3-phase controller inside for non submersible/controller outside for submersible

4

Speed control mode (optional):

PWM Speedamplitude 5V 50-800HZ  Can be customized

0-5V Speed

Potentiometer speed regulationThe resistance range 4.7K~20K

5

Power

DC Power Supply

三.Basic parameters (parameters can be customized)

1

Product model

DC56E-12100PWM

DC56E-12100VR

DC56E-12100S

DC56E-24100PWM

DC56E-24100VR

DC56E-24100S

DC56E-24140PWM

DC56E-24140VR

DC56E-24140S

DC56E-36140PWM

DC56E-36140VR

DC56E-36140S

PWM: PWM(50-800HZ/ 5V)

VR: Potentiometer speed regulation

VS: 0~5V Speed regulation by analog voltage signal

S: Fixed rotational speed

2

Rated Voltage

12V DC

24V DC

24V DC

36V DC


3

Working voltage

5-12V

5-30V

5-26V

5-40V

Within this range, the pump can work normally

4

Rated current

3.5A(4.5A

1.4A(2.2A)

2.7A(3.3A

1.8A(2.2A)

Closed outlet current (open pumping current)

5

power

42W(55W

42W(54W)

65W(80W

65W(80W)

Closed outlet power (open pumping power)

6

Max. Flow rate

2100L/H

2100L/H

2700L/H

2700L/H

Exposure to traffic

7

Max. Head

10M

10M

14M

14M

Static head

8

Min. Input power suply

12V-5A

24V-3A

24V-4A

36V-3A


四.Additional function instructions

1

K-jam protection

When the impurity enters the rotor chamber, the rotor stops running, and the pump stops running as well.

2

Dry run/water shortage protection

When the pump is short of water or idling, the pump will cyclically stop (8 seconds) and run (2 seconds), and the protection strategy can be customized

3

Overloading protection

When the voltage is unstable or exceeds the rated power, the pump will stop working.

4

Power reverse connection

Wrong connection of the power supply(positive and negative), the water pump will stop running, and then re-connected, can work normally.


 

Built-in pump driver

 图片关键词

Suitable for external non-diving occasions


 

Pump driver is external

 图片关键词

Suitable for high temperature, diving installation


Dimensions of pump

图片关键词


Characteristics of three-phase water pump

1.DC Low voltage safe and reliable

2.Three phase brushless sine wave control technology

3.Eliminate high-frequency electromagnetic noise, smooth and silent

4.The pump body and the drive can be separated and resistant to high temperature

5.Magnetic isolation design, leakage proof, waterproof grade IP68.

6.Acid, alkali and salt corrosion resistance, oil resistance, organic solvents and other liquid media (consult in advance)

7.Constant power can be customized (for example, 12V 80W water pump, Constant Power 80W with voltage varying between 12v-24v)

8.Constant speed can be customized (keep the speed unchanged when the load changes)

9.Accurate dry run protection and Jam protection based on current detection (programmable protection mechanism)

10.Soft start eliminates the peak voltage and reduces the starting current

11.Suitable for Music fountain and other high-frequency start- stop application

12.MPPT function can be customized for solar power supply to avoid poor startup when the light is weak.

13.The pump and pump control system can be customized for various application environment requirements